Linda Phone:+86 18059884790      中文版
Product
Product

Contact Us

Contact: YMGK Industrial Control

Phone: +86 18059884790

E-mail: plc66@qq.com

Add: No. 9, 14th Floor, Building 42, Hongshan Lake Road, North Street, Xixiu District, Anshun City, Guizhou Province, China

WOODWARD韦德
9907-149 WOODWARD Steam Turbine digital governor
  • Warehouse: Spot
  • Warranty: 365 days
  • Quality: Original module
  • Condition: New / Used
  • Shipping method: Courier delivery

  • Contact person: Linda
  • Contact number: +86 18059884790
  • WeChat:18059884790
  • E-mail: plc66@qq.com

Product Description

9907-149 WOODWARD Steam Turbine digital governor

9907-149 WOODWARD Steam Turbine digital governor

9907-149 WOODWARD Steam Turbine digital governor

1. Central processing unit

The central processing unit (CPU) consists of a controller, an operator and registers and is integrated into a chip. The CPU is connected to memory, I/O interface, programmer and power supply through data bus, address bus, control bus and power supply bus.

The CPU of small PLC uses 8 bit or 16 bit microprocessor or single chip microcomputer, such as 8031, M68000 and so on, this kind of chip price is very low; The CPU of medium-sized PLC uses 16 bit or 32 bit microprocessor or microcontroller, such as 8086, 96 series microcontroller, etc., this kind of chip is mainly characterized by high integration, fast computing speed and high reliability; And large PLC needs to use high speed bit chip microprocessor.

The CPU commands the PLC control system to complete various tasks according to the function given by the system program in PLC.

Step 2: Memory

The memory in PLC is mainly used to store system programs, user programs and data.

1) System program memory

PLC system program determines the basic function of PLC, the part of the program written by the PLC manufacturer and solidified in the system program memory, mainly has the system management program, user instruction interpretation program and function program and system program call and other parts.

The system management program mainly controls the operation of PLC, so that PLC works in the correct order; The user instruction interpreter converts the PLC user instruction into machine language instruction and transmits it to the CPU for execution; The function program and system program call are responsible for calling different function subroutines and their management programs.

main products.png

→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→→



微信图片_20240410084742.jpg


Address:Unit 2009,No.1733,Luling Road,Siming District,Xiamen,Fujian,China

Company:Xiamen Xiongba E-commerce Co.,Ltd

★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★

Main business:

Bently Nevada:card of 3500 system.(3500/05 framework,3500/15 power module,3500/20 frame interface,3500/22M transient data interface module,3500/25 improved bonding module,3500/32 4-channel relay module,3500/33 16-channel relay module,3500/40M Proximitor displacement monitor module,3500/42M displacement/velocity acceleration monitor,3500/34 Triple module redundant (TMR) relay module,3500/45 displacement monitor,3500/46M monitor module,3500/50 speed module,3500/53 electronic overspeed detection system module,3500/60 temperature monitor module,3500/61 temperature monitor module,3500/62 process variable monitor module,3500/72M piston rod position monitor module,3500/77M cylinder pressure monitor module,3500/92 Communication gateway,3500/93 system display unit,3500/95 system integrated PC display unit,1900/65A four-channel vibration monitor,1900/15 of the monitor,1900/17 Proximitor® monitor,1900/25 vibration monitor,1900/27 vibration monitor,1900/55 Fan monitor,60M100-00 monitoring system module)

HIMA(black horse):F8650 CPU Central module,F8650X CPU Central module,F8650E CPU Central module,F8641 CPU Central module,F8651X Central module,F8652E Central module,F8652X Security control central module,F8627X communication module Coprocessor module,F8628 Communication module Coprocessor module,F8628X communication module Coprocessor module,F8621A communication module Coprocessor module,F35 safety-related controller,etc.

ABB PLC system module DCS system card,including some control system module cards out of production.For example:PM645B,5SHY3545L0014,PM630,07AC91D,SPHSS13,PP845,PFEA111-20,PFEA112-65,Industrial robot spare parts DSQC series, Bailey INFI 90, IGCT, etc., for example: 5SHY6545L0001 AC10272001R0101 5SXE10-0181, 5SHY3545L0009, 5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101, PM866, PM861K01, PM864, PM510V16, PPD512 , PPD113, PP836A, PP865A, PP877, PP881, PP885, 5SHX0660F0001, PM856K01, 3BHL000390P0104 PM851AK01, etc

Triconex:Redundant fault-tolerant control system,the most modern fault-tolerant controller based on triple module redundancy(TMR)structure.(e.g.3721,3625,3008,4351B,3805E)

GE gas turbine cards:IS200 series,DS200 series,etc.(for example:DS200DCFBG1A,IS200TRPGH1B,369-HI-R-M-0-0-0-E,DS200PCCAG1A,VMIVME-7807RC)VMIVME-7807, VMIVME-7750, WES532-111, UR6UH, SR469-P5-HI-A20, IS230SRTDH2A, IS 220PPDAH1B, IS215UCVEH2A , IC698CPE010, IS200SRTDH2ACB, etc

Foxboro:I/A Series system,FBM(field input/output module)sequence control,etc.(for example:FBM201,CP270,CP40B,FCP280,ZCP270).

Woodward:SPC position controller, PEAK150 digital controller, such as 8521-0312 UG-10D, 9907-149, 9907-162,9907-165, 9907-164, 9907-167, TG-13 (8516-038), 8440-1713/D, 5466-258, 8200-226, 5466-409etc

Motorola:MVME 162,MVME 167,MVME1772,MVME177 and other series, such as MVME5100, MVME5500-0163, VME172PA-652SE, VME162PA-344SE-2G and so on

Schneider:140 series processor,control card,power module,etc.(For example:140CPU67160C,140CPU67260,140CPU65150,140CPU43412)

Reliance:discontinued spare parts(such as 0-60002-6,S-D4022,S-D4006-D)

11、XYCOM:I/O,VME board,processor,etc.(For example:XVME-653,XVME-674,XVME-976)

12、Rockwell (ICS TRIPLEX): T8151B,T8311,T8403,T9431, T8480C, etc

13、ABB:DSQC series of industrial robots.(Series:DSQC202,DSQC545A,DSQC627,DSQC352,DSQC679)


Related recommendations