Product Description
The GE IAC2000I Power Supply Interface Board DS200IMCPG1BBA can be connected through a cable to the DS200SDCC Drive Control Board. Connect the cable to the 1PL connector on the Drive Control Board. The board is populated with two green LEDs that indicate the status and activity of the board. However, the LEDs are only active while power is supplied to the board so to view the LEDs you must open the board cabinet door while power is present in the drive.
This potentially exposes you to high voltage and so great care must be taken. If the need arises for you to view the LEDs, open the cabinet door but do not touch anything inside the drive and do not have anything in your hands that might drop in the drive or touch components in the drive.
If anything drops in the drive remove all power to the drive first. Either remove the fuses in the power supplies or use the emergency shutoff device near the drive. A tester can be used to verify that power is not present. Reach in the cabinet and remove the item, if possible.
A hand-held vacuum can be used to clean the components of all debris, dust, and missing items if you can not locate the item that fell. You can restart the drive once the item is retrieved.
The board is populated with one 40-pin connector and one 34-pin connector and they are used to receive and transmit control signals to other boards and components in the drive.