Product Description

The DS200IIBDG1AFA model is an IIBD IGBT Gate Driver Board produced by General Electric for the Mark V DS200 series. There are six optically isolated circuits. One of the major functions of this board is motor terminal voltage isolation.

DS200IIBDG1AFA Technical Specifications

Part NumberDS200IIBDG1AFA
SeriesMark V
ManufacturerGE General Electric
Functional Acronym/AbbreviationIIBD
Product TypeIIBD IGBT Driver Board
WeightLess than 2 pounds

1-230325111J93T.jpg

Product Description

The DS200IIBDG1AFA model is an IIBD IGBT Gate Driver Board produced by General Electric as part of the Mark V DS200 series. The board will perform three primary functions. The three functions are protecting the gate drive for the power-insulated gate bipolar transistors (IGBTs), isolating incoming current feedback, and isolating the motor terminal voltage. There are circuits available in this model; six of them are optically isolated IGBT gate driver circuits, which will give one to each upper and lower IGBTs on the output phases. The other circuits available in this model are voltage, fault feedback, and current circuits for each of the output phases as well. 

Each of the faults that have been reported for the phases will be reported through the terminals on the BDCPL connector; the terminals are /FLTA, /FLTB, and /FLTC. When the IGBT on the DS200IIBDG1AFA model has been commanded to turn on, the IIBD will annunciate the faults associated with the corresponding drive circuit onto the appropriate phase fault line. Two fault types can be generated by the DS200IIBDG1AFA model; they are undervoltage and desaturation faults. When a desaturation fault has been detected during the operation of this model, the associated gate drive module will remove the gate drive to the IGBT.  

1-230325102111524.jpg

The best manual to use when installing and operating the DS200IIBDG1AFA board is the GEI-100180A IIBD IGBT Gate Driver Board Instruction Manual. It has information on the application data for the jumpers, LEDs, input/outputs, and more. 

Frequently Asked Questions about DS200IIBDG1AFA

What are the input/output connectors available on the DS200IIBDG1AFA model?

Overall there are twelve connectors. Three of the connectors are 12-pin ribbon cable connectors used in conjunction with the IGBT snubber board. One of the connectors is a thirty-four-pin ribbon cable connector used to support inputs and outputs with the IMCP board. One of the two-pin connectors is used for temperature sensing. Six of the two-pin connections are used for isolation transformer outputs. The last of the two-pin plug connectors are used for high-frequency AC inputs from the IMCP board.

How does one test this board with the power on?

When testing the board with the power on, there are strict standard practices that need to be taken when working with hazardous voltages. Make sure that you are only using instruments that are rated for high voltages present at the output of the drive. Make sure that you are not probing around the power circuit or board with high voltages present. Also, ensure that the probes being used are only insulated current probes and isolated voltage sensing. 