Product Description
The GE Contactor Driver Board DS200CDBAG1BBB opens and closes a contactor. All power, input signals, and output signals are connected to the board through 1 connector on the board (1TB). The 1TB connector is made up of four sections. Three plug connectors supply the power and signals to the connector. The four sections are 1TBA, 1TBB, 1TBC, and 1TBD. To remove the connector, use a screwdriver to help pry the connectors apart from the board. Before you remove any cables, it is best practice to label all cables to avoid confusion when you install the replacement board.
Also, one fuse connector is located on the board. If replacement is necessary use a 4 amp 125V, 2 AG slow-blow fuse. If the fuse blows often, you might suspect that the board needs to be replaced.
It might be necessary to troubleshoot the board if you suspect the board is not functioning properly. Test points are on board for you test various functions of the board. You’ll need to use isolated test equipment to test the board. One point is the common reference point. The second test point is used for the 15 V dc power supply reference. The third is for the contactor driver reference.
If you call to request service or customer support, be ready to identify the device by the part number before you call. The part number or catalog number is visible on the edge of the board. Write down the identifying information before you call for service or assistance.